FEATURES:
pH
- Equipped with 6.5 inch backlit LCD display
- 1 – 5 points calibration with automatic recognition for USA, NIST and DIN buffers
- Automatic electrode diagnosis shows the pH slope and offset
ORP
- 1 point offset calibration allows adjusting the displayed value to a known standard
- Relative and absolute millivolt modes ensures accurate ORP measurements
ION CONCENTRATION
- 2 – 5 points calibration, including the 8 concentration points, can be selected
- Automatic electrode diagnosis shows calibration points and slopes
- Direct ion concentration readout
- Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency
CONDUCTIVITY/TDS/SALINITY/RESISTIVITY
- 1 -5 points calibration with automatic recognition for conductivity standards
- Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes
- Automatic electrode diagnosis shows calibration points and factors
DISSOLVED OXYGEN
- 1 or 2 points calibration using the air-saturated water and zero oxygen solution
- Salinity and barometric pressure compensation ensures accurate readings
OTHER FEATURES:
- Automatic Temperature Compensation provides accurate readings
- Auto read function senses and locks measurement endpoint
- Calibration reminder
- Setup menu allows setting the number of calibration points, resolution, stability criteria, temperature unit, date and time etc
- Reset function available to default instrument to factory settings
- Expanded memory up to 500 readings
- USB communication interface for data transfer and timed interval readings
Accessories:
- pH/conductivity/dissolved oxygen electrodes
- Temperature probe
- pH buffer sachets
- Conductivity standard solutions
- DO electrolyte solution
- Membrane cap
- Electrode holder
- USB cable
- Power adapter
MODEL SPECIFICATIONS:
Model | MA-pH900 | |
pH |
Range | -2.000~20.000pH |
Resolution | 0.001, 0.01, 0.1pH, selectable | |
Accuracy | ±0.002pH | |
Calibration Points | 1~5 points | |
pH Buffer Options | USA, NIST, DIN, 2 custom buffers | |
ORP |
Range | ±1999.9mV |
Resolution | 0.1, 1mV, selectable | |
Accuracy | ±0.2mV | |
Calibration Points | 1 point | |
Ion |
Range | 0.001~19999 (depending on range of ISE) |
Resolution | 0.001, 0.01, 0.1, 1 | |
Accuracy | ±0.5% FS (Monovalent), ±1% FS (Divalent) | |
Measurement Units | ppm, mg/L, mol/L, mmol/L | |
Calibration Points | 2~5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) | |
Conductivity |
Range | 0.1~2μS/cm (CON-0.1, optional), 2~20mS/cm (CON-1, standard), 20~200mS/cm (CON-10, optional) |
Resolution | 0.001, 0.01, 0.1, 1 | |
Accuracy | ±0.5% FS | |
Calibration Points | 1~5 points | |
Calibration Solutions | 10μS/cm, 84μS/cm, 1413μS/cm, 12.88mS/cm, 111.8mS/cm | |
Temp. Coefficient | Linear (0.0~10.0%/°C), pure water | |
Reference Temp. | 20/25°C | |
Cell Constant | K=0.1, 1, 10 or custom | |
TDS |
Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution | 0.01, 0.1, 1 | |
Accuracy | ±1% FS | |
TDS Factor | 0.1~1.0 (default 0.5) | |
Salinity |
Range | 0.00~42.00psu, 0.00~80.00ppt |
Resolution | 0.01 | |
Accuracy | ±1% FS | |
Resistivity |
Range | 0.00~20.00MΩ |
Accuracy | ±1% FS | |
Resolution | 0.01 | |
Dissolved Oxygen |
Range | 0.00~20.00mg/L, 0.0~200.0% saturation |
Resolution | 0.01mg/L, 0.1% | |
Accuracy | ±0.2mg/L, ±2.0% | |
Calibration Points | 1 or 2 points | |
Barometric Pressure Correction | 60.0~112.5kPa/450~850mmHg, manual | |
Salinity Correction | 0.0~50.0g/L, manual | |
Others |
Temp. Compensation | 0~100°C/32~212°F, manual or automatic |
Memory | 500 data sets | |
Output | USB interface | |
Power Requirements | DC5V power adapter | |
Dimensions mm | 210*188*60 | |
Package Size (W*D*H) mm | 310*240*180 | |
Net Weight (kg) | 1.5 | |
Gross Weight (kg) | 1.7 |